| Parallel Shaft – PZ Series AC Gearmotors |
 |
| General Specifications: |
- Totally enclosed designs for continuous duty applications
- Permanent Split capacitor designs
- Lubrication by semi-fluid grease
- Output shafts utilize needle bearings for high load capacities
- Shafts are hardened Steel
|
| |
| Application Notes: |
| These gearmotors are designed for mounting at any angle, but shaft up with motor below should be avoided to prevent leakage of lubricant into the motor should the motor’s shaft seal fail. Gear-head damage may occur if gearmotor is stalled, especially in the ratios of 60:1 or higher. Overhung load capacities shown are at center of output shaft. Model PZ gearmotors have the same mounting dimensions as Bodine model D and Z gearmotors, Bison 100 gearmotors, and Baldor/Boehm PSS, plus many of the Dayton brand gearmotors. |
| |
Available Ratings: TEFC – 115 Volt - 1.0 Service Factor
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 2 |
100 |
1/150 |
900 |
155 |
| 9 |
100 |
1/15 |
180 |
155 |
| 19 |
100 |
1/15 |
90 |
155 |
| 28 |
100 |
1/15 |
60 |
155 |
| 57 |
56 |
1/15 |
30 |
171 |
| 94 |
36 |
1/15 |
18 |
171 |
| 142 |
24 |
1/15 |
12 |
180 |
| 283 |
12 |
1/15 |
6 |
180 |
|
| |
| Parallel Shaft – P240 Series AC Gearmotors |
 |
| General Specifications: |
- Totally enclosed designs for continuous duty applications
- Permanent Split capacitor designs
- Lubrication by semi-fluid grease
- Output shafts utilize needle bearings for high load capacities
- Shafts are hardened Steel
- First stage gearing is helical type followed by spur type gears
|
| |
| Application Notes: |
| These gearmotors are designed for mounting at any angle, but shaft up with motor below should be avoided to prevent leakage of lubricant into the motor should the motor’s shaft seal fail. Gear-head damage may occur if gearmotor is stalled, especially in the ratios of 60:1 or higher. Overhung load capacities shown are at center of output shaft. Model P240 gearmotors have the same mounting dimensions as Bison’s 224 and 242 gearmotors many Dayton brand gearmotors. |
| |
Available Ratings: Totally Enclosed – 115/230 Volt - 1.0 Service Factor
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 8 |
3445 |
1/15 |
216 |
491 |
| 15 |
250 |
1/15 |
114 |
407 |
| 16 |
391 |
1/6 |
103 |
399 |
| 30 |
135 |
1/15 |
52 |
330 |
| 30 |
295 |
1/6 |
58 |
330 |
| 40 |
219 |
1/6 |
43 |
303 |
| 45 |
92 |
1/15 |
35 |
292 |
| 60 |
157 |
1/6 |
29 |
268 |
| 70 |
61 |
1/15 |
23 |
256 |
| 90 |
103 |
1/6 |
19 |
237 |
| 97 |
43 |
1/15 |
16.5 |
232 |
| 139 |
30 |
1/15 |
11.5 |
208 |
| 156 |
60 |
1/6 |
10.6 |
201 |
|
| |
| Parallel Shaft – P240 Series AC Gearmotors |
 |
| General Specifications: |
- Totally enclosed designs for continuous duty applications
- 60/50 Hz Operation on General Purpose Designs
- 60 Hz Operation on High-Torque Designs
- Gears and bearings are splash lubricated by heavy-duty gear oil
- Oversized output bearings for greater overhung load capacity
- Shafts are of high carbon alloy Stee
- Rugged aluminum die cast housingsl
|
| |
| Application Notes: |
| These gearmotors are designed for mounting at any angle, but shaft up with motor below should be avoided to prevent leakage of lubricant into the motor should the motor’s shaft seal fail. Overhung load capacities shown are at center of output shaft. Model P350 gearmotors have the same mounting dimensions as Bodine’s “E” box and many Baldor/Boehm gearmotors. |
| |
Available Ratings: TEFC – 115/230 Volt – Single-Phase
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 5 |
310 |
1/12 |
336 |
565 |
| 9 |
341 |
1/12 |
180 |
491 |
| 14 |
330 |
1/12 |
124 |
459 |
| 19 |
250 |
1/12 |
91 |
374 |
| 29 |
270 |
1/6 |
58 |
327 |
| 34 |
250 |
1/6 |
50 |
330 |
| 40 |
180 |
1/6 |
43 |
303 |
| 59 |
135 |
1/6 |
29 |
267 |
| 75 |
90 |
1/6 |
23 |
256 |
| 113 |
68 |
1/6 |
15 |
222 |
| 160 |
45 |
1/6 |
10 |
196 |
| 340 |
25 |
1/6 |
5 |
190 |
| High-Torque 1-Phase PE350 Gearmotors with Capacitor Start Motors |
| 58 |
320 |
1/3 |
30 |
300 |
| 85 |
218 |
1/3 |
20 |
300 |
| 173 |
109 |
1/3 |
10 |
300 |
| 345 |
55 |
1/3 |
5 |
300 |
|
| |
PE350 Series - Three-Phase – TEFC – 230/460 Volt
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 58 |
320 |
1/3 |
30 |
300 |
| 85 |
218 |
1/3 |
20 |
300 |
| 173 |
109 |
1/3 |
10 |
300 |
| 345 |
55 |
1/3 |
5 |
300 |
|
| |
| P1100 Series AC Gearmotors |

|
| General Specifications: |
- Totally enclosed designs for continuous duty applications
- 60 Hz input operation
- Gearing designed to withstand 200% momentary shock overloads
- Gears and bearings are splash lubricated by heavy-duty gear oil
- Oversized output bearings for greater overhung load capacity
- Shafts are of high carbon alloy Steel
|
| |
| Application Notes: |
| These gearmotors are designed for mounting at any angle, but shaft up with motor below should be avoided to prevent leakage of lubricant into the motor should the motor’s shaft seal fail. Overhung load capacities shown are at center of output shaft. Model P1100 gearmotors have the same mounting dimensions as Bison 482 gearmotors box and many Dayton brand gearmotors. Three-Phase models are suitable for inverter duty. |
| |
Available Ratings:P1100 Series - Single-Phase – TEFC – 115/230 Volt
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 8 |
975 |
1/4 |
212 |
700 |
| 12 |
1030 |
1/4 |
143 |
700 |
| 18 |
800 |
1/4 |
95 |
700 |
| 26 |
569 |
1/4 |
66 |
650 |
| 59 |
248 |
1/4 |
29 |
625 |
| 133 |
114 |
1/4 |
13 |
525 |
| 18 |
1089 |
1/3 |
95 |
700 |
| 26 |
752 |
1/3 |
66 |
650 |
| 41 |
461 |
1/3 |
42 |
650 |
| 59 |
330 |
1/3 |
29 |
625 |
| 91 |
224 |
1/3 |
19 |
757 |
| 157 |
125 |
1/3 |
11 |
500 |
| 288 |
70 |
1/3 |
6 |
400 |
| 22 |
1105 |
1/2 |
79 |
700 |
| 41 |
700 |
1/2 |
42 |
650 |
| 59 |
496 |
1/2 |
29 |
625 |
| 91 |
336 |
1/2 |
19 |
575 |
| 133 |
229 |
1/2 |
13 |
525 |
|
| |
Available Ratings:P1100 Series - Three-Phase – TEFC – 230/460 Volt
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 18 |
1089 |
1/3 |
95 |
700 |
| 26 |
752 |
1/3 |
66 |
650 |
| 41 |
461 |
1/3 |
42 |
650 |
| 59 |
330 |
1/3 |
29 |
625 |
| 91 |
224 |
1/3 |
19 |
575 |
| 157 |
125 |
1/3 |
11 |
500 |
| 288 |
70 |
1/3 |
6 |
400 |
| 22 |
1105 |
1/2 |
79 |
700 |
| 41 |
700 |
1/2 |
42 |
650 |
| 59 |
496 |
1/2 |
29 |
625 |
| 91 |
336 |
1/2 |
19 |
575 |
| 133 |
229 |
1/2 |
13 |
500 |
| 288 |
100 |
1/2 |
6 |
400 |
|
| |
| Right Angle AC Gearmotors |

|
| General Specifications: |
- Totally enclosed designs for continuous duty applications
- Permanent Split capacitor designs
- Lubrication by permanent oil bath
- Output shaft is interchangeable for left hand or right hand style
- Shafts are hardened Steel
- Worm-type right-angle gearing features hardened steel and bronze worm gears for long life and quiet operation
|
| |
| Application Notes: |
| For optimum seal life, these right angle gearmotors have a lubrication breather positioned for horizontal mounting. For other mountings, the breather plug must be reoriented by u sing a 90-1/8 NPT taper pipe elbow. However, shaft up with motor below should be avoided to prevent leakage of lubricant into the motor should the motor’s shaft seal fail. |
| |
Available Ratings:
Right-Angle - Single-Phase – TEFC/TENV – 115/230 Volt
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 28 |
37 |
1/15 |
60 |
185 |
| 43 |
34 |
1/15 |
40 |
185 |
| 58 |
40 |
1/15 |
30 |
185 |
| 85 |
24 |
1/15 |
20 |
185 |
| 173 |
14 |
1/15 |
10 |
185 |
| 29 |
110 |
1/6 |
60 |
235 |
| 43 |
113 |
1/6 |
40 |
235 |
| 57 |
95 |
1/6 |
30 |
235 |
| 83 |
75 |
1/6 |
20 |
235 |
| 170 |
43 |
1/6 |
10 |
235 |
| 340 |
23 |
1/6 |
5 |
235 |
|
| |
| Inverter Rated SUB-FHP Gearmotors |
 |
| General Specifications: |
- Totally enclosed designs for continuous duty applications
- Inverter Rated insulation system
- Hardened black enamel finish
- Class F insulation
- Shafts are hardened Steel
- Double shielded ball bearings
- 10:1 Speed range operation when operated with a PWM AC inverter
|
| |
| PZ Series AC Gearmotors |
| |
Available Ratings:
Three-Phase – TENV – 230 Volt – Inverter Rated
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 19 |
100 |
1/15 |
90 |
155 |
| 57 |
56 |
1/15 |
30 |
171 |
| 142 |
24 |
1/15 |
12 |
180 |
| 283 |
12 |
1/15 |
6 |
180 |
|
| |
| P240 Series AC Gearmotors |
| |
Available Ratings:
Three-Phase – TEFC – 230 Volt – Inverter Rated
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 16 |
391 |
1/6 |
103 |
399 |
| 30 |
295 |
1/6 |
58 |
330 |
| 60 |
157 |
1/6 |
29 |
268 |
| 90 |
103 |
1/6 |
19 |
330 |
| 156 |
60 |
1/6 |
10.6 |
330 |
|
| |
| PE350 Series AC Gearmotors |
| |
Available Ratings:
Three-Phase – TEFC – 230/460 Volt – Inverter Rated
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 9 |
341 |
1/6 |
180 |
491 |
| 29 |
300 |
1/4 |
58 |
327 |
| 58 |
244 |
1/4 |
30 |
300 |
| 85 |
165 |
1/4 |
20 |
300 |
| 173 |
92 |
1/4 |
10 |
300 |
| 345 |
50 |
1/4 |
5 |
300 |
|
| |
| Right-Angle "13 Series" AC Gearmotors |
| |
Available Ratings:Three-Phase – TEFC – 230 Volt – Inverter Rated
| Output RPM |
F.L. Torque (In.Lbs.) |
Input HP |
Ratio to 1 |
Over-hung Load (Lb.) |
| 29 |
238 |
3/8 |
60 |
235 |
| 43 |
228 |
3/8 |
40 |
235 |
| 86 |
138 |
3/8 |
20 |
235 |
| 172 |
105 |
3/8 |
10 |
235 |
| 345 |
54 |
3/8 |
5 |
235 |
|
| |